Gedevelop - Equipment for glass fiberizer industry

The camera, which is looking at the glass stream, reads information for stream diameter and stream velocity. This information is sent to the central unit with the help of a set of configuration and calibration parameters, calculates the glass flow.

The glass flow meter enhances productivity by continuous measurement of the glass flow individually for each fiberizing unit. Connected to the bushing control, the pull can automatically be controlled within ± 0.5%.

Measuring range 50 – 2000 kg/h (110-4400 lbs/h)

Many installations worldwide have shown that the glass flow measurement is a very profitable investment with a short payback time. The GFM system is capable of handling of 1 up to 10 cameras. Extendible in your own phase.